Controlled Pressure Source (TL)
Generate time-varying pressure differential
- Library:
Simscape / Foundation Library / Thermal Liquid / Sources
Description
The Controlled Pressure Source (TL) block represents an ideal mechanical energy source in a thermal liquid network. The pressure differential is controlled by the input physical signal at port P. The source can maintain the specified pressure differential across its ports regardless of the mass flow rate through the source. There is no flow resistance and no heat exchange with the environment. A positive signal at port P causes the pressure at port B to be greater than the pressure at port A.
The energy balance at the source is a function of the energy flow rates through ports A and B and the work done on the fluid:
where:
ϕA is the energy flow rate into the source through port A.
ϕB is the energy flow rate into the source through port B.
ϕwork is the isentropic work done on the fluid.
The isentropic work term is
where:
ϕwork is the isentropic work done on the thermal liquid.
pA is the pressure at port A.
pB is the pressure at port B.
ρavg is the average liquid density,
Assumptions and Limitations
There are no irreversible losses.
There is no heat exchange with the environment.
Ports
Input
Conserving
Parameters
Extended Capabilities
Version History
Introduced in R2013b