Flow Resistance (G)

General resistance in a gas branch

  • Flow Resistance (G) block

Libraries:
Simscape / Foundation Library / Gas / Elements

Description

The Flow Resistance (G) block models a general pressure drop in a gas network branch. The pressure drop is proportional to the square of the mass flow rate and to the density of the gas. The constant of proportionality is determined from a nominal operating condition specified in the block dialog box.

Use this block when the only data available for a component is its pressure drop as a function of its mass flow rate. Combine the block with others to create a custom component that more accurately captures the pressure drop that it induces—for example, a heat exchanger based on a chamber block.

Mass Balance

The volume of gas inside the flow resistance is assumed to be negligible. The mass flow rate in through one port must then exactly equal the mass flow rate out through the other port:

m˙A+m˙B=0,

where m˙A and m˙B are defined as the mass flow rates into the component through ports A and B, respectively.

Energy Balance

Energy can enter and leave the flow resistance through the gas conserving ports only. No heat exchange occurs between the wall and the environment. In addition, no work is done on or by the fluid. The energy flow rate in through one port must then exactly equal the energy flow rate out through the other port:

ϕA+ϕB=0,

where ϕA and ϕB are the energy flow rates into the flow resistance through ports A and B.

Momentum Balance

The relevant external forces on the fluid include those due to pressure at the ports and those due to viscous friction at the component walls. Gravity is ignored as are other body forces. Expressing the frictional forces in terms of a loss factor ξ yields the semi-empirical expression:

Δp=ξm˙22ρS2,

where:

  • Δp is the pressure drop from port A to port B—that is, pA + pB.

  • ξ is the loss factor.

  • ρ is the fluid density.

  • S is the flow area.

The pressure drop equation is implemented with two modifications. First, to allow for a change in sign upon reversal of flow direction, it is rewritten:

Δp=ξm˙|m˙|2ρS2,

where the pressure drop is positive only if the mass flow rate is too. Second, to eliminate singularities due to flow reversal—which can pose a challenge for numerical solvers during simulation—it is linearized in a small region of near-zero flow:

Δp=ξm˙m˙2+m˙Th22ρS2,

where m˙Th is a threshold mass flow rate below which the pressure drop is linearized. The figure shows the modified pressure drop against the local mass flow rate (curve I):

  • Above m˙Th, the pressure drop approximates that expressed in the original equation (curve II) and it varies with m˙2. This dependence is commensurate with that observed in turbulent flows.

  • Below m˙Th, the pressure drop approximates a straight line with slope partly dependent on m˙Th (curve III) and it varies with m˙. This dependence is commensurate with that observed in laminar flows.

For ease of modeling, the loss factor ξ is not required as a block parameter. Instead, it is automatically computed from the nominal condition specified in the block dialog box:

ξ2S2=ρ*Δp*m˙*2,

where the asterisk (*) denotes a value at the nominal operating condition. Underlying all of these calculations is the assumption that the threshold mass flow rate m˙Th is much smaller than the nominal value m˙*. Replacing the fraction ξ/(2S2) in the expression for the pressure drop yields:

Δp=ρ*Δp*ρm˙*2(m˙m˙2+m˙Th2).

or, equivalently:

Δp=Cm˙ρm˙2+m˙Th2,

where C is a constant of proportionality between the pressure drop across the flow resistance and the local mass flow rate. It is defined as:

C=ρ*Δp*m˙*2.

If the fluid density is assumed to be invariant, then its nominal and actual values must always be equal. This is the case whenever the nominal value is specified in the block dialog box as 0—a special value used to signal to the block that the fluid density is a constant. The ratio of the two is then 1 and the fraction C/ρ reduces to:

Cρ=Δp*m˙*2.

Ports

Conserving

expand all

Gas conserving port associated with the inlet or outlet of the flow resistance. This block has no intrinsic directionality.

Gas conserving port associated with the inlet or outlet of the flow resistance. This block has no intrinsic directionality.

Parameters

expand all

Pressure drop from inlet to outlet at a known operating condition. The block uses the nominal parameters to calculate the constant of proportionality between the pressure drop and the mass flow rate.

Mass flow rate through the component at a known operating condition. The block uses the nominal parameters to calculate the constant of proportionality between the pressure drop and the mass flow rate.

Mass density inside the flow resistance at a known operating condition. The block uses the nominal parameters to calculate the constant of proportionality between the pressure drop and the mass flow rate. Set this parameter to zero to ignore the dependence of the pressure drop on the fluid density.

Flow area at the ports of the flow resistance. The ports are assumed to be identical in size.

Ratio of the threshold mass flow rate to the nominal mass flow rate. The block uses this parameter to calculate the threshold mass flow rate—and ultimately to set the limits of linearization for the pressure drop.