Main Content

HRTIM

Use the higher resolution timer module and its parameters to configure the interrupts.

Suspend update events during preload write timers select

Enable to configure the timers to suspend update events during preload write timers.

Settings

Default: off

on

Synchronized counter start timers select

Enable to configure the timers to synchronize counter start timers.

Settings

Default: off

on

Enable interrupts select

Select the timer to enable the interrupts.

Settings

Default: TimerA

TimerB

TimerC

TimerD

TimerE

TimerF

MainTimer

Global

Faults

Enable delayed protection trigger interrupt

Select this parameter to enable delayed protection trigger interrupt for the selected higher resolution timer module.

Settings

Default: off

on

Enable counter reset/roll-over event interrupt

Select this parameter to enable counter reset/roll-over event interrupt for the selected higher resolution timer module.

Settings

Default: off

on

Enable channel# reset interrupt

Select this parameter to enable channel# reset interrupt for the selected higher resolution timer module.

Settings

Default: off

on

Enable channel# set interrupt

Select this parameter to enable channel# set interrupt for the selected higher resolution timer module.

Settings

Default: off

on

Enable capture# event interrupt

Select this parameter to enable capture# event interrupt for the selected higher resolution timer module.

Settings

Default: off

on

Enable update interrupt

Select this parameter to enable update interrupt for the selected higher resolution timer module.

Settings

Default: off

on

Enable repetition event interrupt

Select this parameter to enable repetition event interrupt for the selected higher resolution timer module.

Settings

Default: off

on

Enable compare# event interrupt

Select this parameter to enable compare event interrupt for the selected higher resolution timer module.

Settings

Default: off

on

Enable register update event

Select this parameter to enable register update event for the selected higher resolution timer module.

To enable this parameter, set the Enable interrupts select to MainTimer.

Settings

Default: off

on

Enable synchronization update event

Select this parameter to enable synchronization update event for the selected higher resolution timer module.

To enable this parameter, set the Enable interrupts select to MainTimer.

Settings

Default: off

on

Enable DLL calibration done interrupt

Select this parameter to enable DLL calibration done interrupt for the selected higher resolution timer module.

To enable this parameter, set the Enable interrupts select to Global.

Settings

Default: off

on

Enable burst period completed interrupt

Select this parameter to enable burst period completed interrupt for the selected higher resolution timer module.

To enable this parameter, set the Enable interrupts select to Global.

Settings

Default: off

on

Enable system fault interrupt

Select this parameter to enable system fault interrupt for the selected higher resolution timer module.

To enable this parameter, set the Enable interrupts select to Faults.

Settings

Default: off

on

Enable fault# interrupt

Select this parameter to enable system fault interrupt for the selected higher resolution timer module.

To enable this parameter, set the Enable interrupts select to Faults.

Settings

Default: off

on