What is the correct way to invoke AUTOSAR Client operation using AUTOSAR Blockset?
5 views (last 30 days)
Show older comments
MathWorks Support Team
on 30 May 2017
Edited: MathWorks Support Team
on 1 Jun 2021
I am trying to generate C code from a Simulink model configured using AUTOSAR in Simulink, but I get the following error when I attempt to use the "Invoke AUTOSAR Server Operation" block in my SWC:
ERROR: Error: Simulink Coder Error in block: block type "S-Function": Invoke AUTOSAR Server Operation block resides in a model mapped to a multi-instance AUTOSAR Software Component. This is not supported for the AUTOSAR Target. You must place this block in a model mapped to a single-instance AUTOSAR Software Component.
Also, I have seen that this block is no longer available in the latest MATLAB releases. Is it not possible to use the "Invoke AUTOSAR Server Operation" block to model my SWC in Simulink?
Accepted Answer
MathWorks Support Team
on 1 Jun 2021
Edited: MathWorks Support Team
on 1 Jun 2021
The “Invoke AUTOSAR Server operation” block is no longer the recommended approach to model Client-Server communication. Because the block has been discontinued, it cannot be guaranteed that it will work correctly in the newer releases.
Instead, we recommend the use of
, and to utilize the AUTOSAR dictionary and the code mappings to configure the C-S communication, as we explain in the
. This approach provides a more predictable and efficient behaviour, in line with the current product direction.