Replacement Name: int
Name for int data type in generated code
Model Configuration Pane: Code Generation / Data Type Replacement
Description
The Replacement Name: int parameter specifies the name to use for the built-in data type int in the generated code.
Dependencies
To enable this parameter, select the Specify custom data type names parameter.
Settings
If a value is not specified, the code generator uses the Code Generation Name:
int_Tif Data type replacement isUse coder typedefs.intif Data type replacement isUse C data types with fixed-width integers.
You can specify a replacement name by using one of the following:
A
Simulink.AliasTypeobject.The Simulink Name built-in data type name.
To use a Simulink.AliasType object:
Set the
BaseTypeobject property tointn.Set the
HeaderFileobject property to the name of the header file that provides the type definition.In the Replacement Name column, specify the
intn.
To use the Simulink Name, in the Replacement
Name column, specify
intn.
n is the number of bits displayed in the Configuration
Parameters dialog box, Hardware Implementation pane >
Number of bits: int.
An error occurs, if
A replacement data type specification is inconsistent with the Simulink Name data type.
The
Simulink.AliasTypeobject has the Data scope parameter set toExported.
Recommended Settings
| Application | Setting |
|---|---|
| Debugging | No impact |
| Traceability | A valid value |
| Efficiency | No impact |
| Safety precaution | No recommendation |
Programmatic Use
Parameter: ReplacementTypes, replacementName.int |
| Type: character vector |
Value: The Simulink Name or the name of a Simulink.AliasType, where the object exists in the base workspace. |
Default: '' |
Version History
Introduced in R2007a