Use the timer module and its parameters to configure the interrupts.

Timer group

Select the timer group to configure the timer parameters.

Settings

Default: Advanced Timers 1/8

General Purpose 2/3/4/5

Basic Timers 6/7

General Purpose 9/10/11/12/13/14

Show TIM# configurations

Select the timer to configure the timer parameters.

Settings

Default: off

on

Start timer during model initialization

Enable Start Timer during model initialization parameter to start the counter during model initialization.

The starting of counter for any timer module is initiated only if any of the Timer, Timer capture, Encoder or PWM Output block are available in the model for that timer module

To start/stop the counter in runtime, disable the Start Timer during model initialization parameter and select Enable Counter Input parameter in the block. An input of 1 to the corresponding input will start the counter and 0 will stop the counter.

.

Settings

Default: on

off

Enable Trigger Interrupt

Select this parameter to enable trigger interrupt for the selected timer module.

Settings

Default: off

on

Enable Capture Compare # Interrupt

Select this parameter to enable capture compare interrupt for the selected timer module.

Settings

Default: off

on

Enable Update Interrupt

Select this parameter to enable update interrupt for the selected timer module.

Settings

Default: off

on

Enable Break Interrupt

Select this parameter to enable break interrupt for the selected timer module.

Settings

Default: off

on

Enable Commutation Interrupt

Select this parameter to enable commutation interrupt for the selected timer module.

Settings

Default: off

on

Enable Index Interrupt

Select this parameter to enable index interrupt for the selected timer module.

Settings

Default: off

on

Enable Direction Interrupt

Select this parameter to enable direction interrupt for the selected timer module.

Settings

Default: off

on

Enable Transition Error Interrupt

Select this parameter to enable transition error interrupt for the selected timer module.

Settings

Default: off

on

Enable Index Error Interrupt

Select this parameter to enable index error interrupt for the selected timer module.

Settings

Default: off

on