Heat Flow Rate Sensor
Ideal heat flow meter
Libraries:
Simscape /
Foundation Library /
Thermal /
Thermal Sensors
Description
The Heat Flow Rate Sensor block represents an ideal heat flow meter, that is, a device that converts a heat flow passing through the meter into a control signal proportional to this flow.
Connect this sensor in series with the block where you want to measure the heat flow because heat flow is a Through variable (for the thermal domain). Connecting the sensor in parallel may affect the simulation results because it is analogous to adding a bypass connection line between the connection points. A series connection within an existing line does not affect the simulation results and provides an accurate measurement.
Connections A and B are thermal conserving ports. Port H is a physical signal port that outputs the heat flow value.
The block positive direction is from port A to port B.
Ports
Output
Conserving
Extended Capabilities
Version History
Introduced in R2007b