Guideline: jc_0141: Usage of the Switch blocks
Description
Verifies that the Switch block control input (the second input) is a Boolean value and that the block is configured to pass the first input when the control input is nonzero.
This check requires a Simulink® Check™ license.
Check Parameterization
This check does not include sub-checks because the MAB modeling guideline provides only one sub ID.
For reference, the MAB guideline sub ID(s) that are recommended for use by the NA-MAAB and JMAAB modeling standards organizations are:
- NA-MAAB — a 
- JMAAB — a 
Results and Recommended Actions
| Condition | Recommended Action | 
|---|---|
| The Switch block control input (second input) is not a Boolean value. | Change the data type of the control input to Boolean. | 
| The Switch block is not configured to pass the first input when the control input is nonzero. | Set the block parameter Criteria for passing first input to u2 ~=0. | 
Capabilities and Limitations
- Does not run on library models. 
- Analyzes content of library linked blocks. By default, the input parameter Follow links is set to - on.
- Analyzes content in masked subsystems that have no workspaces and no dialogs. 
- Allows exclusions of blocks and charts. 
Edit-Time Checking