Three-Phase Parallel RLC Branch
Implement three-phase parallel RLC branch
Library
Simscape / Electrical / Specialized Power Systems / Passives
Description
The Three-Phase Parallel RLC Branch block implements three balanced branches consisting each of a resistor, an inductor, a capacitor, or a parallel combination of these. Use the Branch type parameter to select elements you want to include in each branch.
Negative values are allowed for resistance, inductance, and capacitance.
Parameters
- Branch type
- Select the elements you want to include in the branch. The R letter defines the resistor, the L letter defines the inductor, and the C letter defines the capacitor. Select Open circuit to define an open circuit (R=inf, L=inf, C=0). Only existing elements are displayed in the block icon. Default is - RLC.
- Resistance R
- The branch resistances, in ohms (Ω). Default is - 1.
- Inductance L
- The branch inductances, in henries (H). Default is - 1e-3.
- Capacitance C
- The branch capacitances, in farads (F). Default is - 1e-6.
- Measurements
- Select - Branch voltagesto measure the three voltages across the Three-Phase Parallel RLC Branch block terminals.- Select - Branch currentsto measure the three total currents (sum of R, L, C currents) flowing through the Three-Phase Parallel RLC Branch block.- Select - Branch voltages and currentsto measure the three voltages and the three currents of the Three-Phase Parallel RLC Branch block.- Default is - None.- Place a Multimeter block in your model to display the selected measurements during the simulation. In the Available Measurements list box of the Multimeter block, the measurements are identified by a label followed by the block name. - Measurement - Label - Branch voltages - Ua:- Branch currents - Ia:
See Also
Multimeter, Three-Phase Parallel RLC Load, Three-Phase Series RLC Branch, Three-Phase Series RLC Load
Version History