Timed Ramp signal after a trigger in simulink

60 views (last 30 days)
Bugra Calis
Bugra Calis on 6 Dec 2021
Edited: Arda on 18 Jan 2024
I want to generate a ramp function in order to drive a motor up to a certain speed when a condition is satisfied. Whenever I wanted to do something like this the ramp signal starts from the beginning of the simulation. I used enabled signal block but it did not help.
Also is there a way to make the ramp signel independent from the time step of the simulation. For example no matter what is the time step I want to generate a ramp signal goes from 0 to 3000 in 2 seconds.

Answers (1)

Marcelo
Marcelo on 16 Dec 2021
You can try an Integrator with constant "1" input, wich gives a block whose output is "out = time".
Then, when your trigger signal becomes TRUE, you reset the Integrator and plug the "1" constant.
And, multiplying the output, you can change the ramp slope.
In this example, we have a ramp starting in t=3s and incresing 1500 per second.
  2 Comments
Arda
Arda on 18 Jan 2024
Edited: Arda on 18 Jan 2024
But how is the increasing stopped after two seconds?
Secondly, why do we set the constant of the Integrator to "1"? What does it provide to have output = time?