Step Response on linear analysis tool is scaled differently from simulink scope
4 views (last 30 days)
Show older comments
I am trying to find the transfer function of a simple high pass filter using simscape and linear analysis tool. I built up the circuit as shown, the output i get from the simulink scope is scaled differently from step response of the transfer function i get from linear analysis tool.Step response on linear analysis tool starts at 1 versus simulink scope output of 0.8125(which is correct). I would like to know how to correct it.
0 Comments
Answers (1)
Ankit Bhardwaj
on 26 Apr 2017
One cause for this issue might be the incorrect usage of Linear Analysis Points. Please keep in mind that using "Open-loop Input/Output" will break existing feedback loops. If you are interested in performing linear analysis on a closed loop model, a combination of "Input Perturbation" and "Output Measurement" points should be used to designate the input and the output, respectively.
It is also important to keep in mind that linearizing a non-linear model will inherently cause the step response to look different. For instance, if your model contains a saturation block, it will be converted to a gain during linearization. As a result, if the signal is reaching the saturation limit during simulation, this behavior cannot be reflected in the linearized step response.
0 Comments
See Also
Categories
Find more on Trimming and Linearization in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!