Setting the Values of Trigger Properties
About Trigger Properties
Most trigger properties can be set in the same way you set any
other image acquisition object property: referencing the property
as you would a field in a structure using dot notation. For example,
you can specify the value of the TriggerRepeat
property,
where vid
is a video input object created using
the videoinput
function.
vid.TriggerRepeat = Inf
For more information, see Configuring Image Acquisition Object Properties.
Some trigger properties, however, are interrelated and require
the use of the triggerconfig
function to set their
values. These properties are the TriggerType
, TriggerCondition
,
and TriggerSource
properties. For example, some TriggerCondition
values
are only valid when the value of the TriggerType
property
is 'hardware'
.
Specifying Trigger Type, Source, and Condition
Setting the values of the TriggerType
, TriggerSource
,
and TriggerCondition
properties can be a two-step
process:
Determine valid configurations of these properties by calling the
triggerinfo
function.Set the values of these properties by calling the
triggerconfig
function.
For an example of using these functions, see Using a Hardware Trigger.
Determining Valid Configurations
To find all the valid configurations of the TriggerType
, TriggerSource
,
and TriggerCondition
properties, use the triggerinfo
function,
specifying a video input object as an argument.
config = triggerinfo(vid);
This function returns an array of structures, one structure for each valid combination of property values. Each structure in the array is made up of three fields that contain the values of each of these trigger properties. For example, the structure returned for an immediate trigger always has these values:
TriggerType: 'immediate' TriggerCondition: 'none' TriggerSource: 'none'
A device that supports hardware configurations might return the following structure.
TriggerType: 'hardware' TriggerCondition: 'risingEdge' TriggerSource: 'TTL'
Note
The character vectors used as the values of the TriggerCondition
and TriggerSource
properties
are device specific. Your device, if it supports hardware triggers,
might support different condition and source values.
Configuring Trigger Type, Source, and Condition Properties
To set the values of the TriggerType
, TriggerSource
,
and TriggerCondition
properties, you must use the triggerconfig
function.
You specify the value of the property as an argument to the function.
For example, this code sets the values of these properties for a hardware trigger.
triggerconfig(vid,'hardware','risingEdge','TTL')
If you are specifying a manual trigger, you only need to specify the trigger type value as an argument.
triggerconfig(vid,'manual')
You can also pass one of the structures returned by the triggerinfo
function
to the triggerconfig
function and set all three
properties at once.
triggerconfig(vid, config(1))
See the triggerconfig
function
documentation for more information.
Note