Why does it take long or stops when i use simscape electrical components instead of simscape electrical(power electronic) components to run a power electronics topology.
2 views (last 30 days)
Show older comments
I was referring to the single phase grid connected inverter online and when it is constructed using power electronics components, the topology runs smooth and ends but when i use simscape electrical components it takes very long and cannot reach the end. The reason i use the simscape electrical components is because i want to use the thermal port block in the mosfet to perform thermal analysis, but even without the thermal block, it is still running very slow. May i know why or what is causing this in the topology or is there a way to solve this.
0 Comments
Answers (1)
Sabin
on 4 Feb 2023
The way the gate driver is implemented doesn't look right. I believe because of that the model is a bit stiff and is very slow. Probably better to use the Half Bridge Driver block. Check the Analysis of Synchronous Buck Converter with Self Turn-On example for more insights about how to control the N-Channel MOSFET.
0 Comments
See Also
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!