Hello,
I designed the LQG regulator for the system I want.
The LQG I designed leads to a state that converges to 0.
I would like to change the result so that the controller converges to a separate reference target, but this is where the problem arises.
It is very complicated to explain my system, so in the question I would like to learn how to do it through a simple example.
I wonder how to reflect the reference target through the example provided by the MATLAB site.
The code below is the initialization & setting code of the above UFO controller example.
The system is designed to converge the states with radian and rad/s information to 0, respectively.
I want to change this system so that it finally converges to a non-zero reference state.
How can I design the controller with reference state in this example?
close all
% Initial Conditions
x0 = [3; % 3 radians
0]; % 0 rad/s
% System Dynamics
A = [0 1;
0.01 0];
B = [0;
1];
C = [1 0];
D = 0;
% Control Law
Q = [1 0; % Penalize angular error
0 1]; % Penalize angular rate
R = 1; % Penalize thruster effort
K = lqr(A,B,Q,R);
% Closed loop system
sys = ss((A - B*K), B, C, D);
% Run response to initial condition
t = 0:0.005:30;
[y,t,x] = initial(sys, x0, t);
0 Comments
Accepted Answer
Paul
on 31 Oct 2022
Edited: Paul
on 31 Oct 2022
Hi JS,
One common way to track a reference input with a Type 1 system is to use integral control by augmenting the plant with an integrator and applying LQR to the augmented plant.
4 Comments
Paul
on 20 Nov 2022
As to the first part, it sounds like you're trying to do something like this:
% Initial Conditions
x0 = [3; % 3 radians
0]; % 0 rad/s
% System Dynamics
A = [0 1;
0.01 0];
B = [0;
1];
% C = [1 0];
C = eye(2); % output both states, the first state is the output to control
D = 0;
sysp = ss(A,B,C,D,'InputName','u','OutputName',{'y' 'x2'});
% Control Law
Q = [1 0; % Penalize angular error
0 1]; % Penalize angular rate
R = 1; % Penalize thruster effort
K = lqr(A,B,Q,R);
% negate the second element of K for negative feedback of x2
% negative feedback on the first state will be achieved via the error signal
K(2) = -K(2);
sysc = ss(K,'OutputName','u','InputName',{'e' 'x2'});
% error signal
s = sumblk('e = r - y');
syscl = connect(sysp,sysc,s,'r','y');
step(syscl)
As to the second part, I'm afraid I can't offer any inputs.