How to converge 3 phases of simulink voltage onto a simscape VI measurement which accepts 1 port
15 views (last 30 days)
Show older comments
As mentioned, I'm wanting working between simulink and simscape libraries. My voltage source block outputs 3 phases of voltage, although the measurement block that I need accepts a single connection with 3 signals. Notsure how to get around this as cant use a mux. Any help would be much appreciated!
0 Comments
Answers (3)
Joel Van Sickel
on 8 Feb 2023
This block lets you switch between one line representations of 3 phase wires: https://www.mathworks.com/help/sps/ref/phasesplitter.html;jsessionid=12d81ff0f3faaf382533c296ec45
0 Comments
Mohamad Nazir
on 8 Feb 2023
All you have to do is right click on the current & voltage sensor, choose Simscape > Modeling option > expanded three-phase ports, as you can see in the attached screenshot
0 Comments
Sabin
on 8 Feb 2023
You can directly use a Controlled Voltage Source (Three-Phase) in Simscape Electrical. Assuming that the Subsystem you have is using blocks from the Simscape technology you can directly connect it to the measurement sensor by changing the 'Modeling option' dropdown in the Current and Voltage Sensor (Three-Phase) to 'Expanded three-phase ports'. I hope this helps.
0 Comments
Communities
More Answers in the Power Electronics Control
See Also
Categories
Find more on Electrical Sensors in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!