Clear Filters
Clear Filters

Simscape IL actuator connecting port A and B using valve

1 view (last 30 days)
The directional valve 304 is set to connect port 2 and 4 (port A and B of the piston). Now, when applying a force on the piston R, an error occurs. When connecting A and B directly (without valve 304) the piston moves back to cap C, as expected. Why does it not work with the valve though? There is a connection between 2 and 4, I checked, for a brief moment there is mass flow from port A to B, before the error pops up.
  1 Comment
Yifeng Tang
Yifeng Tang on 8 May 2024
I took a quick look at the model and simulation results. Looks like one cylinder is moving, as the pressure builds up inside. Its movement then engaged two hardstops and later push/pull on the other cylinder (the one where the error is triggered). That piston moved a little but the directional valves connecting to the fluid chambers are fully closed so no fluid can come in. The chamber that's expanding therefore sees a huge & quick pressure drop. Is the valve supposed to do something at this moment by allowing the flow through? I don't know enough about the system itself to comment further.

Sign in to comment.

Answers (0)

Categories

Find more on Simscape Fluids in Help Center and File Exchange

Products


Release

R2023a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!