SLDV check subsystem compatibility , call cycles detected

45 views (last 30 days)
Amrith
Amrith on 17 Nov 2024 at 20:26
Commented: Amrith about 21 hours ago
Hi,
I am new to simulink and I am trying to check compatibility of a model (file attached) but I get error "call cycles detected"
I dont know how to resolve this or what exactly is the issue kindly provide any information to help me reolve this
Thank you
  7 Comments
Walter Roberson
Walter Roberson on 18 Nov 2024 at 18:42
Does that use Simulink Designer Verifier product? I do not have that product. Without it, I do not see any kind of Design Verifier option.
Amrith
Amrith on 18 Nov 2024 at 19:02
@Walter Roberson Thank you for cheking .
Yes it might need to be added , it is part of design , verification and testing models

Sign in to comment.

Answers (1)

Sreeram
Sreeram on 19 Nov 2024 at 3:59
Hi Amrith,
I was able to reproduce the error on my end. As the error suggests, call cycles are not supported for Simulink Design Verifier.
A potential reason for that is that the chart uses undirected event broadcasts using the function “send”. The documentation recommends preferring directed event broadcasts over undirected event broadcasts to prevent unwanted recursion:
You may read more about the error and ways to avoid it in this MATLAB Answers post:
For more details on how to detect and fix cyclic behaviour, this documentation might help:
I hope it helps.
  1 Comment
Amrith
Amrith about 19 hours ago
Thank you so much.
The error messages in simulink and matlab is often not very useful I hope they improve this

Sign in to comment.

Categories

Find more on Model Compatibility in Help Center and File Exchange

Tags

Products

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!