Why the sim doesn't seems to respect the Centrifugal Pump Characteristics in Simscape (IL)?
    3 views (last 30 days)
  
       Show older comments
    
Hello! I'm having a problem and i don't know exactly what is happening. I have the following simple system, where a centrifugal pump pumps water (from the isothermal liquid predefined properties block) into a pipe and back to the reservoir:

I'm using the default centrifugal pump characteristics for the Centrifugal Pump (IL) block, running at 1770 rpm. The pipe is a 100m 1 in² cross sectional pipe. I plugged both a gauge pressure sensor to the pump discharge and a flow sensor for the loop. When i run the system, i get crazy high results for the pressure and for the flow, like the follow:


750 lpm and 220 head pressure (m, converted from bar * 10) at steady state. I assumed the centrifugal pump would -cap- the flow at the block parameter "Maximum capacity at zero head", which is the default 80 lpm at 1770 rpm.
Am i wrong to assume this behavior? If so, what is the recommended way to cap the centrifugal pump to behave like the real one in that case?
1 Comment
  Yifeng Tang
    
 on 13 Jun 2025
				Please consider attaching the model so the community can reproduce and better understand your issues.
Answers (0)
See Also
Categories
				Find more on Simscape Fluids in Help Center and File Exchange
			
	Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!