Mass-spring-Damper system with external signal
10 views (last 30 days)
Show older comments
I am trying to simulate a mass-spring-damper system with a signal from my workspace thou it gives me this error. Please help.
Error in port widths or dimensions. Invalid dimension has been specified for input port 2 of 'sensitivity/Sum1'.
Error in port widths or dimensionsError in port widths or dimensions. Output port 1 of 'sensitivity/Sum' has 26 elements. This port does not accept the dimensions (or orientation) specified by the output signal.
Below is my block arrangeme

0 Comments
Answers (1)
Fangjun Jiang
on 5 Feb 2019
Assume your data has 700 data points, you need to make your y a 700x2 matrix.
The first column is the time step, the second column is the data. For example
y=[0.01*(1:700);ones(1,700)].';
0 Comments
See Also
Categories
Find more on Sources in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!