How to solve this issue Variable 'X' is not fully defined on some execution paths.
8 views (last 30 days)
Show older comments
Dear All,
I have a code into a MATLABFUNCTION block of Simulink that jump out this error message "
Variable 'CONDICIONTRAMO' is not fully defined on some execution paths. Function 'Battery_Control/Function_Cruz_v2' (#25.1881.1895), line 57, column 12: "CONDICIONTRAMO" Launch diagnostic report."
Anyone of you can help me out to find the way to solve this ? Please.
function [SOC_CC, Bat_charge] = BUsage(top, SOC, SOC_Seg, SOCint, W_demand, Power_PV)
if SOC>=SOC_Seg
SOC_CC=0;
Bat_charge=0;
return
else
if SOC>=SOCint
SOC_CC=1;
Bat_charge=0;
end
if SOC<=SOCint
if (top>=8)||(top<=9) && Power_PV>W_demand
CONDICIONTRAMO = 1;
disp('Llano 1 de 8 a 9')
elseif (top>=8)||(top<=9) && Power_PV<W_demand
CONDICIONTRAMO = 2;
disp('"-" Llano 1 de 8 a 9')
elseif (top>=10)||(top<=13) && Power_PV>W_demand
CONDICIONTRAMO = 3;
disp('Punta 1 de 10 a 13')
elseif (top>=10)||(top<=13) && Power_PV<W_demand
CONDICIONTRAMO = 4;
disp('"-"Punta 1 de 10 a 13')
elseif (top>=14)||(top<=17) && Power_PV>W_demand
CONDICIONTRAMO = 5;
disp('Llano 2 de 14 a 17')
elseif (top>=14)||(top<=17) && Power_PV<W_demand
CONDICIONTRAMO = 6;
disp('"-"Llano 2 de 14 a 17')
elseif (top>=18)||(top<=21)&& Power_PV>W_demand
CONDICIONTRAMO = 7;
disp('Punta 2 de 18 a 21')
elseif (top>=18)||(top<=21)&& Power_PV<W_demand
CONDICIONTRAMO = 8;
disp('"-"Punta 2 de 18 a 21')
elseif (top>=22)||(top<=23)&& Power_PV>W_demand
CONDICIONTRAMO = 9;
disp('Llano 3 de 22 a 23:59')
elseif (top>=22)||(top<=23)&& Power_PV<W_demand
CONDICIONTRAMO = 10;
disp('"-"Llano 3 de 22 a 23:59')
elseif (top>=24)||(top<=8) && Power_PV<W_demand
CONDICIONTRAMO =11;
disp('Valle de 24 a 8')
end
switch CONDICIONTRAMO
case 1
SOC_CC=1;
Bat_charge=0;
case 2
SOC_CC=0;
Bat_charge=0;
case 3
SOC_CC=1;
Bat_charge=0;
case 4
SOC_CC=0;
Bat_charge=0;
case 5
SOC_CC=1;
Bat_charge=0;
case 6
SOC_CC=0;
Bat_charge=0;
case 7
SOC_CC=1;
Bat_charge=0;
case 8
SOC_CC=0;
Bat_charge=0;
case 9
SOC_CC=1;
Bat_charge=0;
case 10
SOC_CC=0;
Bat_charge=0;
case 11
SOC_CC=1;
Bat_charge=1;
otherwise
disp('No')
end
end
end
end
0 Comments
Accepted Answer
Jan
on 30 Jun 2021
Edited: Jan
on 30 Jun 2021
Insert a definition of CONDICIONTRAMO = -1 (or NaN, or 12) either on top of the code, before the IF branchs, or in a finaly else branch:
...
elseif (top>=24)||(top<=8) && Power_PV<W_demand
CONDICIONTRAMO =11;
disp('Valle de 24 a 8')
else
CONDICIONTRAMO = 12;
end
But then Bat_charge is not defined in all branchs. Add a default value for this variable also.
By the way, the Switch/Case-Block is hard to read. Maybe this is tougher:
% 1 2 3 4 5 6 7 8 9 10 11 12
SOC_CC_V = [1 0 1 0 1 0 1 0 1 0 1 NaN];
Bat_charge_V = [0 0 0 0 0 0 0 0 0 0 1 NaN];
SOC_CC = SOC_CC_V(CONDICIONTRAMO);
Bat_charge = Bat_charge_V(CONDICIONTRAMO);
7 Comments
Jan
on 2 Jul 2021
As far as I understand, this is another problem. If so, please open a new thread to get support.
More Answers (0)
See Also
Categories
Find more on Sources in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!