Answered
Can we change parameters inside 'block parameters' of Ideal IGBT block?
Hi, A little head-up on your task. I see that you are calculating the efficiency by using Simulink blocks. Even though theore...

1 month ago | 1

Answered
why is it impossible to use the PID tuning app when tuning a PID controller used in circuits that have PWM switchings?
Dea Hassan, The failure in the linearization process is normal due to the discontinuities associated to switching events. This...

2 years ago | 0

Answered
Why is the settling value of my TF so high when compared to my output value? How can I resolve this?
Dear Samuel, the discrepancy you're getting may be explained by the presence of other nonidealities you model with Simscape Elec...

2 years ago | 0

Answered
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
Dear Samuel, The difficulties you are encountering are understandable since when you tune a specific gain of your PID controlle...

2 years ago | 0

Answered
In "frestimate(modelname,op,io,in)", it is required for each of the linearization input I/O points that the sample time of the Simulink signal where it is located is one of the following:
Hi, both input linearization point and output measurement point are required to be equally sampled and must match the perturbati...

3 years ago | 3

| accepted