Question
What is the correct angular velocity in Simscape electrical demo "Synchronous Machine Initialization with Loadflow"?
Data explorer reports the angular velocity at 60Hz as 37.6 rad/s not 60*2*pi (377). see example ee_loadflow_sm_initializatio...
2 years ago | 1 answer | 0
1
answerWhy is my signal builder not giving precise outputs?
Try increasing the Decimation and especially the Refine factor. I've needed a refine factor of 10 to recover ms precision in ti...
4 years ago | 0
Question
Three-Phase Transformer (Two Windings)
There is an error in the winding's per unit parameter for Leakage Reactance. The mask documentation calls for Leakage Inductanc...
10 years ago | 1 answer | 0