Feeds
Same source but different signals between the Data Aquisition Toolbox and the NI softwares
Hi Manisha, We did find a kind of solution. We installed the old NI-DAQ 7.4.4. driver and we do have access to discontinuous...
12 years ago | 0
Same source but different signals between the Data Aquisition Toolbox and the NI softwares
There is no AI.Channel.Coupling Here is AI.Channel: Index: ChannelName: HwChannel: InputRange: SensorRange: UnitsRan...
12 years ago | 0
Same source but different signals between the Data Aquisition Toolbox and the NI softwares
Hi Manisha, Thank you for answering. In both NI and Data Acquisition Toolbox, the property 'InputType' is set to Pseudodiffe...
12 years ago | 0
Question
Same source but different signals between the Data Aquisition Toolbox and the NI softwares
Hello, I have some trouble with the data acquisition toolbox. The simple program below works great for transient signals cen...
12 years ago | 4 answers | 0