Serial communication with Query Instrument
1 view (last 30 days)
Show older comments
Danilo NASCIMENTO
on 27 Oct 2013
Commented: Walter Roberson
on 23 Jan 2018
Hi, Do you know if the Query Instrument from Instrument Control Toolbox can really catch a signal from a serial connection? I'm using a Virtual Serial Connection to emulate the serial port and I am using Proteus with a dsPic to generate a train of pulses, I already put a oscilloscope in Proteus, and the pulse is going through the serial port, the only problem is the Query Instrument I am using in Simulink that is giving only zero.
0 Comments
Accepted Answer
Walter Roberson
on 28 Oct 2013
Serial ports can only receive serial data that is correctly formed into a series, with an appropriate start bit, a series of data bits (usually 8 of them), and a the stop bit. Even within that format, decoding of the pulses is determined by voltage levels, with voltages below -3V being a bit representing logic 1, and voltages above +3V being a bit representing logic 0. By agreement, least significant bit is sent first.
Thus, if you have a train of pulses none of which -3V or lower, then no start bit will ever be deemed to have been seen, and no data will be deemed to have been transmitted. If no pulse is above +3V then no stop bit will be deemed to have been seen. The required timing of the pulses depends upon the agreed serial port rate.
2 Comments
Walter Roberson
on 23 Jan 2018
No. Only pulses formatted as blocks with start bit and stop bit can be handled by serial.
More Answers (0)
See Also
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!