What's wrong with my decoupled power flow program

9 views (last 30 days)
Nguyen
Nguyen on 11 Dec 2014
Edited: Nguyen on 11 Dec 2014
I have write a decoupled power flow program. The code has no problem. However, my results about the reactive power generation are negative. This should be positive. It seems that unreasonable. Can anyone who are experts in power engineering help me,thank you very much?
  • m = find(Bus_type ~= 1);
  • n = find(Bus_type == 3);
  • p = find(Bus_type == 1);
  • %Build the B' and B'' matrix
  • B1 = inv(imag(Y(m,m)));
  • B2 = inv(imag(Y(n,n)));
  • %Find the real and reactive power mismatch
  • theta_est = zeros(length(ID_bus),1); %Initial Estimate of Angle
  • iteration = 200; %Number of iteration
  • iter = 1;
  • %dP = zeros(length(ID_bus),1);
  • %dQ = zeros(length(ID_bus),1);
  • %Start iteration
  • for iter = 1:iteration
  • P = zeros(length(ID_bus),1);
  • Q = zeros(length(ID_bus),1);
  • for i=1:length(ID_bus)
  • for j=1:length(ID_bus)
  • P(i) = P(i) + Vhold(i)*Vhold(j)*abs(Y(i,j))*cos(angle(Y(i,j))-theta_est(i)+theta_est(j));
  • Q(i) = Q(i) - Vhold(i)*Vhold(j)*abs(Y(i,j))*sin(angle(Y(i,j))-theta_est(i)+theta_est(j));
  • end
  • end
  • dP = P_sch(m) - P(m);
  • dQ = Q_sch(n) - Q(n);
  • %Find the mismatch Angle
  • dtheta = -B1*dP./Vhold(m);
  • %Update the angle
  • theta_est(m) = theta_est(m) + dtheta;
  • %Find the mismatch Voltage
  • dV = -B2*dQ./Vhold(n);
  • %Update the Voltage
  • Vhold(n) = Vhold(n) + dV;
  • %Convergence tolerance
  • Tolerance = max(max(abs(dP)),max(abs(dQ)));
  • end

Answers (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!