No load test of PMSM motor
9 views (last 30 days)
Show older comments
I tried to simulate a 3 phase surface mount PMSM motor with the real parameters. At first, I applied just a 3 phase voltage. I want to see the torque on the shaft in no load condition. So, I did not apply a torque on its shaft. However, I am reading a 0 toruqe in the measured parameters of the motor. Even without any load and torque, I should read a torque. Do you know what is the problem?
Thank you.
0 Comments
Answers (1)
Balavignesh
on 14 Feb 2023
Hi Mohammad,
I understand that you are trying to simulate the motor for no load conditions by leaving the input torque terminal as it is.
As per documentation (Three-phase permanent magnet synchronous machine with sinusoidal or trapezoidal back electromotive force, or five-phase permanent magnet synchronous machine with sinusoidal back electromotive force - Simulink (mathworks.com)), the mode of operation (motor/generator) is determined by the value provided to the torque terminal (A positive torque signal indicates motor mode and a negative signal indicates generator mode). In your case, as the terminal is left as it is, the mode of operation is not set, leading to zero output torque.
Regards,
Balavignesh
0 Comments
See Also
Categories
Find more on Motor Drives in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!