Clear Filters
Clear Filters

How can fix that error in this simulation?

1 view (last 30 days)
Merve Ala
Merve Ala on 19 Apr 2023
Answered: Walter Roberson on 19 Apr 2023
I am working on this simulation and it gives me this error. What can I do?
An error occurred while running the simulation and the simulation was terminated
Caused by:
  • Derivative of state '1' in block 'hwmid/Aerodynamic_Data/total forces/Subsystem/Integrator' at time 0.0 is not finite. The simulation will be stopped. There may be a singularity in the solution. If not, try reducing the step size (either by reducing the fixed step size or by tightening the error tolerances)
Component:Simulink | Category:Block error

Answers (1)

Walter Roberson
Walter Roberson on 19 Apr 2023
Derivatives not being finite at time zero are typically mistakes in initialization -- in particular, forgetting that input signals that are updated by a feedback model need to be initialized
But it is also not uncommon to have a model that effectively has a division by t (time) and forgetting that at time 0 that means a division by 0.

Categories

Find more on Event Functions in Help Center and File Exchange

Tags

Products


Release

R2023a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!