issues on Heat exchanger in simscape TL-MA
4 views (last 30 days)
Show older comments
the model created seems not to behave phisically correct: heat exchanger reduces both temperature of TL and moisture air.
it should heat up air, cooling down fluid instead.
7 Comments
Accepted Answer
Yifeng Tang
on 26 May 2023
Setting reasonable parameters to discribe the nominal conditions for the heat exchanger seem to resolve the issue. Pay particular attention to units and type of information needed (mass flow vs. volumetric flow). The port size matters as well because the local velocity calculated based on port size and mass flow is also part of the energy flow calculation.
0 Comments
More Answers (0)
See Also
Categories
Find more on Thermal Liquid Library in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!