num_simulations = 10000;
%Common parameters
Discount_Rate_min = 0.06; % assume 6-8%
Discount_Rate_max = 0.08;
Discount_Rate_values = unifrnd(Discount_Rate_min, Discount_Rate_max, [num_simulations, 1]);
Lifetime = 20; % years
Electricity_Cost_values = 0.185; %EUR/kWh
FLH = [4000,6000,8000];
LHV = 33.33; %kWh/kgH2
%SOEC 2020 parameters
CAPEX_System_SOEC_mean_2020 = 4200; %$/kW
CAPEX_System_SOEC_std_2020 = 50;
CAPEX_System_SOEC_values_2020 = normrnd(CAPEX_System_SOEC_mean_2020, CAPEX_System_SOEC_std_2020, [num_simulations,1]);
CAPEX_System_SOEC_values_2020(CAPEX_System_SOEC_values_2020 < 2800) = 2800;
CAPEX_System_SOEC_values_2020(CAPEX_System_SOEC_values_2020 > 5600) = 5600;
CAPEX_Stack_SOEC_values_2020 = 0.5*CAPEX_System_SOEC_values_2020; % 50% of CAPEX system
CAPEX_SOEC_values_2020 = (CAPEX_System_SOEC_values_2020 + CAPEX_Stack_SOEC_values_2020);
OPEX_SOEC_values_2020 = 3; % 3% of CAPEX/a
System_Efficiency_SOEC_mean_2020 = 0.775;
System_Efficiency_SOEC_std_2020 = 0.01;
System_Efficiency_SOEC_values_2020 = normrnd(System_Efficiency_SOEC_mean_2020, System_Efficiency_SOEC_std_2020, [num_simulations,1]);
System_Efficiency_SOEC_values_2020(System_Efficiency_SOEC_values_2020 < 0.74) = 0.74;
System_Efficiency_SOEC_values_2020(System_Efficiency_SOEC_values_2020 > 0.81) = 0.81;
%SOEC 2030 parameters
CAPEX_System_SOEC_mean_2030 = 1800; %$/kW
CAPEX_System_SOEC_std_2030 = 50;
CAPEX_System_SOEC_values_2030 = normrnd(CAPEX_System_SOEC_mean_2030, CAPEX_System_SOEC_std_2030, [num_simulations,1]);
CAPEX_System_SOEC_values_2030(CAPEX_System_SOEC_values_2030 < 2800) = 800;
CAPEX_System_SOEC_values_2030(CAPEX_System_SOEC_values_2030 > 5600) = 2800;
CAPEX_Stack_SOEC_values_2030 = 0.5*CAPEX_System_SOEC_values_2030; % 50% of CAPEX system
CAPEX_SOEC_values_2030 = (CAPEX_System_SOEC_values_2030 + CAPEX_Stack_SOEC_values_2030);
OPEX_SOEC_values_2030 = 3; % 3% of CAPEX/a
System_Efficiency_SOEC_mean_2030 = 0.805;
System_Efficiency_SOEC_std_2030 = 0.01;
System_Efficiency_SOEC_values_2030 = normrnd(System_Efficiency_SOEC_mean_2030, System_Efficiency_SOEC_std_2030, [num_simulations,1]);
System_Efficiency_SOEC_values_2030(System_Efficiency_SOEC_values_2030 < 0.77) = 0.77;
System_Efficiency_SOEC_values_2030(System_Efficiency_SOEC_values_2030 > 0.84) = 0.84;
%PEM 2020 parameters
CAPEX_System_PEM_mean_2020 = 1450; %$/kW
CAPEX_System_PEM_std_2020 = 50;
CAPEX_System_PEM_values_2020 = normrnd(CAPEX_System_PEM_mean_2020, CAPEX_System_PEM_std_2020, [num_simulations,1]);
CAPEX_System_PEM_values_2020(CAPEX_System_PEM_values_2020 < 1100) = 1100;
CAPEX_System_PEM_values_2020(CAPEX_System_PEM_values_2020 > 1800) = 1800;
CAPEX_Stack_PEM_values_2020 = 0.35*CAPEX_System_PEM_values_2020; % 35% of CAPEX system
CAPEX_PEM_values_2020 = (CAPEX_System_PEM_values_2020 + CAPEX_Stack_PEM_values_2020);
OPEX_PEM_values_2020 = 3;
System_Efficiency_PEM_mean_2020 = 0.58;
System_Efficiency_PEM_std_2020 = 0.01;
System_Efficiency_PEM_values_2020 = normrnd(System_Efficiency_PEM_mean_2020, System_Efficiency_PEM_std_2020, [num_simulations,1]);
System_Efficiency_PEM_values_2020(System_Efficiency_PEM_values_2020 < 0.56) = 0.56;
System_Efficiency_PEM_values_2020(System_Efficiency_PEM_values_2020 > 0.6) = 0.6;
%PEM 2030 parameters
CAPEX_System_PEM_mean_2030 = 1075; %$/kW
CAPEX_System_PEM_std_2030 = 50;
CAPEX_System_PEM_values_2030 = normrnd(CAPEX_System_PEM_mean_2030, CAPEX_System_PEM_std_2030, [num_simulations,1]);
CAPEX_System_PEM_values_2030(CAPEX_System_PEM_values_2030 < 650) = 650;
CAPEX_System_PEM_values_2030(CAPEX_System_PEM_values_2030 > 1500) = 1500;
CAPEX_Stack_PEM_values_2030 = 0.35*CAPEX_System_PEM_values_2030; % 35% of CAPEX system
CAPEX_PEM_values_2030 = (CAPEX_System_PEM_values_2030 + CAPEX_Stack_PEM_values_2030);
OPEX_PEM_values_2030 = 3;
System_Efficiency_PEM_mean_2030 = 0.655;
System_Efficiency_PEM_std_2030 = 0.01;
System_Efficiency_PEM_values_2030 = normrnd(System_Efficiency_PEM_mean_2030, System_Efficiency_PEM_std_2030, [num_simulations,1]);
System_Efficiency_PEM_values_2030(System_Efficiency_PEM_values_2030 < 0.63) = 0.63;
System_Efficiency_PEM_values_2030(System_Efficiency_PEM_values_2030 > 0.68) = 0.68;
%AEC 2020 parameters
CAPEX_System_AEC_mean_2020 = 950; % $/kW
CAPEX_System_AEC_std_2020 = 50;
CAPEX_System_AEC_values_2020 = normrnd(CAPEX_System_AEC_mean_2020, CAPEX_System_AEC_std_2020, [num_simulations,1]);
CAPEX_System_AEC_values_2020(CAPEX_System_AEC_values_2020 < 500) = 500;
CAPEX_System_AEC_values_2020(CAPEX_System_AEC_values_2020 > 1400) = 1400;
CAPEX_Stack_AEC_values_2020 = 0.35*CAPEX_System_AEC_values_2020; % 35% of CAPEX system
CAPEX_AEC_values_2020 = (CAPEX_System_AEC_values_2020 + CAPEX_Stack_AEC_values_2020);
OPEX_AEC_values_2020 = 3;
System_Efficiency_AEC_mean_2020 = 0.665;
System_Efficiency_AEC_std_2020 = 0.01;
System_Efficiency_AEC_values_2020 = normrnd(System_Efficiency_AEC_mean_2020, System_Efficiency_AEC_std_2020, [num_simulations,1]);
System_Efficiency_AEC_values_2020(System_Efficiency_AEC_values_2020 < 0.63) = 0.63;
System_Efficiency_AEC_values_2020(System_Efficiency_AEC_values_2020 > 0.7) = 0.7;
%AEC 2030 parameters
CAPEX_System_AEC_mean_2030 = 625; % $/kW
CAPEX_System_AEC_std_2030 = 50;
CAPEX_System_AEC_values_2030 = normrnd(CAPEX_System_AEC_mean_2030, CAPEX_System_AEC_std_2030, [num_simulations,1]);
CAPEX_System_AEC_values_2030(CAPEX_System_AEC_values_2030 < 400) = 400;
CAPEX_System_AEC_values_2030(CAPEX_System_AEC_values_2030 > 850) = 850;
CAPEX_Stack_AEC_values_2030 = 0.35*CAPEX_System_AEC_values_2030; % 35% of CAPEX system
CAPEX_AEC_values_2030 = (CAPEX_System_AEC_values_2030 + CAPEX_Stack_AEC_values_2030);
OPEX_AEC_values_2030 = 3;
System_Efficiency_AEC_mean_2030 = 0.68;
System_Efficiency_AEC_std_2030 = 0.01;
System_Efficiency_AEC_values_2030 = normrnd(System_Efficiency_AEC_mean_2030, System_Efficiency_AEC_std_2030, [num_simulations,1]);
System_Efficiency_AEC_values_2030(System_Efficiency_AEC_values_2030 < 0.65) = 0.65;
System_Efficiency_AEC_values_2030(System_Efficiency_AEC_values_2030 > 0.71) = 0.71;
% Calculate 2020 SOEC LCOH values
term1_S_2020 = LHV ./ (System_Efficiency_SOEC_values_2020);
term2_S_2020 = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_S_2020 = (OPEX_SOEC_values_2020 / 100);
term4_S_2020 = CAPEX_SOEC_values_2020 ./ FLH;
LCOH_SOEC_2020 = term1_S_2020 .* ((term2_S_2020 ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S_2020) .* term4_S_2020 + Electricity_Cost_values);
% Calculate 2020 PEM LCOH values
term1_P_2020 = LHV ./ (System_Efficiency_PEM_values_2020);
term2_P_2020 = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_P_2020 = (OPEX_PEM_values_2020 / 100);
term4_P_2020 = CAPEX_PEM_values_2020 ./ FLH;
LCOH_PEM_2020 = term1_P_2020 .* ((term2_P_2020 ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_P_2020) .* term4_P_2020 + Electricity_Cost_values);
% Calculate 2020 AEC LCOH values
term1_A_2020 = LHV ./ (System_Efficiency_AEC_values_2020);
term2_A_2020 = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_A_2020 = (OPEX_AEC_values_2020 / 100);
term4_A_2020 = CAPEX_AEC_values_2020 ./ FLH;
LCOH_AEC_2020 = term1_A_2020 .* ((term2_A_2020 ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_A_2020) .* term4_A_2020 + Electricity_Cost_values);
% Calculate 2030 SOEC LCOH values
term1_S_2030 = LHV ./ (System_Efficiency_SOEC_values_2030);
term2_S_2030 = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_S_2030 = (OPEX_SOEC_values_2030 / 100);
term4_S_2030 = CAPEX_SOEC_values_2030 ./ FLH;
LCOH_SOEC_2030 = term1_S_2030 .* ((term2_S_2030 ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S_2030) .* term4_S_2030 + Electricity_Cost_values);
% Calculate 2030 PEM LCOH values
term1_P_2030 = LHV ./ (System_Efficiency_PEM_values_2030);
term2_P_2030 = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_P_2030 = (OPEX_PEM_values_2030 / 100);
term4_P_2030 = CAPEX_PEM_values_2030 ./ FLH;
LCOH_PEM_2030 = term1_P_2030 .* ((term2_P_2030 ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_P_2030) .* term4_P_2030 + Electricity_Cost_values);
% Calculate 2030 AEC LCOH values
term1_A_2030 = LHV ./ (System_Efficiency_AEC_values_2030);
term2_A_2030 = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_A_2030 = (OPEX_AEC_values_2030 / 100);
term4_A_2030 = CAPEX_AEC_values_2030 ./ FLH;
LCOH_AEC_2030 = term1_A_2030 .* ((term2_A_2030 ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_A_2030) .* term4_A_2030 + Electricity_Cost_values);
Using the code data, I would like to compare LCOH of six items with histogram.
Image is like the picture.
What is command for it?
3 Comments