Clear Filters
Clear Filters

Issue with Configuring Plant Model from ECU TEST tool

7 views (last 30 days)
Im currentyl working on setting up an ECU TEST project for my remote Test bench. I face the following error while trying to conenct to the test bench model port,
Could anyone help me resolve this issue?
Thank you,
Best Regards,
Dhivya

Answers (1)

Guilherme Costa Nascimento
Hi Dhivya,
This could be happening because the Simulink Test Support Package for ASAM XIL is picking up the wrong version of MATLAB in the case where you have multiple versions installed.
Please execute these two commands in the MATLAB Command Window of the version you are using:
comserver('register','User','current');
enableservice('AutomationServer', true);
This should ensure that the correct version is registered with the Support Package.
  1 Comment
Dhivya
Dhivya on 15 May 2024
Hi Costa,
Thank you for the Solution !
The issue is resolved currently. Thank you again.