PID Tuning tells me the system has closed loop stability even though it doesn't

11 views (last 30 days)
Hello everyone,
I am using the PID Tuning App to design a PID controler for my plant. It works pretty good, the systems reaction is pretty solid and the PID Tuning tells me that I have closed loop stability.
The problem is, when I check the root locus, it has some poles with positive real values, indicating my system is unstable. There is even a branch that is not reaching into the negative pane, so it would seem impossible to stabilize the system.
Also, if I design the controler with the "sisotool", I get the same result.
Is there something I might be missing?
Thank you in advance for any help!
Is it sometimes acceptable to work with a system even though it is not stable?

Answers (1)

Arkadiy Turevskiy
Arkadiy Turevskiy on 24 Apr 2015
Could it be the same issue as in this question ?
If not, then please attach your models/files- hard to troubleshoot otherwise.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!