Simulink tapped delay block with vector inputs
Show older comments
All,
I have often needed a "shift-register" function in Simulink that can accept vector inputs. The tapped delay only supports scalar inputs. I typically build this function using the "Matlab Function" block.
How do other people solve this problem? Is there a built-in solution I am not aware of?
Maybe someone from MathWorks is reading these questions? It is a pretty big gap that there is no built-in way to build a shift register with vectors.
Thanks.
Accepted Answer
More Answers (1)
praguna manvi
on 17 Mar 2025
0 votes
The "Tapped Delay" block natively accepts only scalar inputs. A workaround to pass vector inputs is to use a "Buffer" block, setting the "Overlap" property to one less than the buffer size. Here is a useful discussion thread on a similar use case:
For more information on the "Buffer" block, refer to the following link:
Categories
Find more on Sources in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!