SYstem Id doubt

3 views (last 30 days)
Nakul
Nakul on 2 Jan 2012
Dear all,
I am designing a black box model using subspace identification (PO-MOESP) which has 19 outputs and 13 inputs. Each data set has over 10000 samples My question is, whenever I use the same data set for identification and validation I get quite a descent fit(estimate) and vaf. But as soon as I use a different dataset for validation , I get almost 0 vaf for all the outputs and -ve fit. What could be the reason for such a drastic change? n how can I solve this issue
Nakul

Answers (1)

Rajiv Singh
Rajiv Singh on 17 Mar 2012
That means that the model is not reliable. What orders did you try? Usually, this indicates unnecessarily high orders.