Simulink simulation output at Zero second doubt
    6 views (last 30 days)
  
       Show older comments
    
    Rahul krishna
 on 8 May 2016
  
    
    
    
    
    Commented: Rahul krishna
 on 8 May 2016
            I have done the following simulink model. One with direct addition of constant blocks and the other addition with a unit delay in between. In the first case the output (2) is available in the 0th second but the block with unit delay the output is available at 0.2 seconds, but i expected 1 at 0th second. why there is no output at 0th second. Please help. I am a beginner.
0 Comments
Accepted Answer
  Azzi Abdelmalek
      
      
 on 8 May 2016
        
      Edited: Azzi Abdelmalek
      
      
 on 8 May 2016
  
      I ran your model, and it shows the value 1 at 0 sec. Also, the output is always available, even when the output is equal to 0. Zero is a value.