Basic question on visualising AC voltage signal in scope

3 views (last 30 days)
Im trying to visualise a sinusoidally varying voltage which is in complex form. Now I know that this is sinusoidal as it comes from an AC generator.
But when I connect it to a scope all i get is a flat line.
What am I doing wrong?

Answers (1)

Sebastian Castro
Sebastian Castro on 20 May 2016
I'm guessing the model you're using is in phasor mode, as that voltage measurement is a complex phasor.
The way phasor mode works, this is expected. We can determine that, for each phase voltage you are plotting on that scope:
  • The magnitude sqrt(Real^2 + Imag^2) is the amplitude of the sinusoid
  • The phase atan2(Imag,Real) is the phase of the sinusoid
  • The frequency is assumed to be a fundamental frequency specified in the powergui block (typically 50 or 60 Hz)
- Sebastian
  1 Comment
ck12345
ck12345 on 21 May 2016
I tried that but still the magnitude is a flat line.
I don't think its giving me the instantaneous value. Rather what an AC voltmeter would measure. How do I get it to measure the instantaneous value?

Sign in to comment.