Hi,
If I'm setting the data type of an output port to say fixdt(0,32,0.1,10) this will not result in the corresponding value output scaling in the generated code (RTW-EC). Is this the correct behavior or am I doing something wrong?
Many thanks in advance!
0 Comments
Answers (1)
Kaustubha Govind
on 13 Mar 2012
Does inserting a Data Type Conversion block in front of the output port help? You need to configure the Data Type Conversion block to output the desired type.
2 Comments
Kaustubha Govind
on 14 Mar 2012
Turn on "Format>Port/Signal Displays>Port Data Types" from your model. What is the displayed datatype going into the outport?