How can I calculate moving 3 sec RMS value of a continuous signal in Simulink?
0 Comments
Answers (1)
Akhilesh Mishra
on 11 Jul 2017
The moving RMS can be taken using the Moving RMS block. The Solver setting for the model has to be set as 'Fixed-step' with Fixed-step size set.
Please refer to the snapshot attached below for an example. The sample time is 0.01, and a Moving RMS block is used to calculate the RMS of the sine wave for 3s.
The documentation link for this block can be found in the following link- https://www.mathworks.com/help/dsp/ref/movingrms.html