Using simulink SimState with different look up table data
4 views (last 30 days)
Show older comments
Thijs van Krimpen
on 6 Apr 2018
Answered: Thijs van Krimpen
on 11 May 2018
So my problem is that i have a simulink model with a slow start up and afterwards decent run time. I'd like to use the restart (load initial state) functionality. However when i change a lookup table I get the error that the model has changed and simulink cannot use the initial state.
The lookup table contains the data i wish to change for each loadcase. with zero values for the first 15 seconds, and im trying to restart after 10 second so the data should be the same.
Is there a workaround for this issue?
Or to rephrase, how to load simulation specific parameters into simulink whilst still being able to load an initial sim state?
0 Comments
Accepted Answer
More Answers (1)
Mark McBroom
on 7 Apr 2018
Try using fast restart. This option disables some consistency checks performed during model initialization and may let you get around this problem. Obviously the burden is on you to ensure that the changed lookup table values don't influence the saved simstate.
0 Comments
See Also
Categories
Find more on Simulink Environment Customization in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!