I get the error. " NaN's cannot be converted to Logicals" when trying to linearize my model. The model runs actually with no problem. the problem arises only when linearizing the model in control design. I don't know what exactly simulink does during linearazation that causes this error.
2 Comments
Accepted Answer
Adam Danz
on 9 Aug 2018
This will replicate your error:
v = [1 0 1 1 0 NaN 0 1 0 0];
logical(v)
Error using logical
NaN's cannot be converted to logicals.
My guess is that you're using logical() to convert a variable with 0s and 1s that also have NaN values.
If that's the case, you need to decide whether NaNs should be a 0 or a 1. In this example, I set NaNs to 0.
v = [1 0 1 1 0 NaN 0 1 0 0];
v(isnan(v)) = 0;
logical(v)
Or you can remove the NaNs
v = [1 0 1 1 0 NaN 0 1 0 0];
v(isnan(v)) = [];
logical(v)
4 Comments
Tim
on 8 Dec 2018
Hi, could you please explain how exactly you added v(isnan(v)) = []; to the block output?
More Answers (3)
Barton Bacon
on 24 Oct 2023
This just happened to me and the culprit was a square root block I had recently added to a simulation.... believe it or not. Changing the square root block to a power block and using .5 as the exponent for some reason allowed the linearization to proceed without the "NaN's cannot be converted into logicals" error. MATHWORKS what the heck is going on in the square root and reciprocal square block that would produces this problem in linearization? Those blocks linearize fine by themshelves in a their own block diagram. In a complicated simulation, not so much apparently.
0 Comments
Welid Benchouche
on 4 Jan 2019
hello guys, can you please help me , i get the same error on model predictive control when linearizing Rc=0.15
2 Comments
Apicha Kittirattanachai
on 21 Aug 2020
please kindly explain "integrators in your model they should be responsible for "NaNs" "
How are integrators setting for response the NaN value ?
My problem is appear in mpc toolbox when linearize of toolbox.
Thankyou.
Ahmed Elgohary
on 5 Mar 2022
Edited: Ahmed Elgohary
on 5 Mar 2022
Well, i got the same error with model predictive control during linearization and i could solve the problem by changing the range of simulink operating point as shown at the figure. So it was from [0 1] and i made it from [0.1 1] for example as you want for the upper limit but the main problem was related to using zero for lower limit during the linearization.