F28M35 Simulink ePWM block
5 views (last 30 days)
Show older comments
Hi all
I am new to this device and blocks associated with it and I have read the block description page. I am trying to do some ADC in and PWM outs. But for all the examples the ePWM blocks are orange and with an input port of "WA", however if I drag the exactly same block from the library the block will not have any input port even if all the settings are the same. I believe the input is to drive the ePWM clock.
Please help me, the image is attached below.
Thanks.
0 Comments
Answers (1)
Vineeth Nair
on 31 Aug 2018
To get the "WA" input port , open block parameters ->Under counter compare tab-> set the "Specify CMPA via" parameter to - Input port. Note that, this is not the port to drive ePWM clock. To know more about the ePWM block, its timer properties etc. you can go to this link .
3 Comments
Vineeth Nair
on 3 Sep 2018
1. Priority of ADC's can be changed. In Configuration parameters-> Hardware implementation -> Select required Hardware board. Under Target hardware resources->There are settings for ADC, where priority can be set to high priority. By default it's in round robin mode.
2.Here you can also see settings for clocking. The clock frequency can be changed here. Attaching screenshot of these settings tabs.