PMSM Drive system Linearization
1 view (last 30 days)
Show older comments
Ali Bashabsheh
on 30 Aug 2018
Commented: Mudit Verma
on 30 Aug 2020
Hello Everybody
I am working on a MATLAB Simulink model for PMSM drive system, my system is controlling the motor's torque. I am facing a problem in linearizing the plant. I have tried to tune PID controller parameters, but the plant cannot be linearized. I don't understand the problem enough to fix it effectively, hereby I tried a lot of things randomly but never worked, in the attached file I tried some manual tuning method but it doesn't result in good dynamic response because a huge overshoot is observed in the output currents and torque :(
Can anyone help in this regard. The Simulink file is attached.
Thanks in advance
Ali Bashabsheh
0 Comments
Accepted Answer
Arkadiy Turevskiy
on 29 Oct 2018
Hi there,
Linearization does not work for models with discontinuities such as PWM and power semiconductors.
There are a couple of techniques we recommend:
1. Do ac sweep (frequency response estimation) and use that frequency response for tuning - see this example .
Hope this helps.
Arkadiy
1 Comment
Mudit Verma
on 30 Aug 2020
Autotuner not working in my model there is no PId gains showing they are showning 0 and only frequencies are showing in display block
More Answers (0)
Communities
More Answers in the Power Electronics Control
See Also
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!