Unit conversion in Simbiology
Show older comments
Hi to all,
Does Simbiology performs unit conversion when, for example, a species in the membrane is transformed into a cytoplasmatic product? It certainly does some conversion but I’m not sure is the right one. For example, 1 molecule/micrometer^2 is transformed by an irreversible reaction from the compartment X that has 6 micrometer^2 capacity into 6 nM of the product in compartment Y that has 1 micrometer^3 capacity. According to my numbers it should have been 10nM instead of 6nM.
Am I missing something here?
Thanks in advance,
Omar
2 Comments
George Kamin
on 3 Mar 2017
You comment about accessing the "simulation settings" to disable unit checking, this no longer exists in R2016AB
Arthur Goldsipe
on 3 Mar 2017
Hi,
In R2016b, you can disable unit checking directly while viewing the model by going to the toolstrip tab labeled MODEL and clicking on the button named "Convert Units." You will also still find a button labeled "Simulation Settings" when viewing a task, like a simulation. Just go to the toolstrip tab labeled EDITOR and look for the gear icon.
-Arthur
Accepted Answer
More Answers (0)
Communities
More Answers in the SimBiology Community
Categories
Find more on Scan Parameter Ranges in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!