How can I initialize internal variable of s-function every simulation?
17 views (last 30 days)
Show older comments
Hello :D
I'm having a problem with s-function.
I'd like to initialize all value of s-function, but I can't.
I think the last value of internal variable is not initialized when I execute simulation again.
So, before execute simulation, I'd like to initialize internal state of s-function.
I'm wating for your answers.
Thank you.
0 Comments
Accepted Answer
Mark McBroom
on 22 Mar 2020
Add code to the mdlStart() or mdlInitialize() functions in the SFunctionto reset state variables.
2 Comments
Ani Singh
on 24 Mar 2020
Put your S-function inside an enabled subsystem with "Output when disabled" set to "reset" - this will call your mdlInitializeConditions method every time the subsystem is disabled.