Svpwm 2 error block on the Equivalent model
Show older comments
Hi, I'm trying to simulate this circuit on simunlink and I got these two errors on the equivalent model
I'm not sure what is the problem here ; it says "error in port dimensions"
Block error simulink : input is a one dimentional vector with 6 elements

Answers (1)
Looks like the problem is in the Universal Bridge. The dimension of 'g' input is expected to be 6 as we have 6 switching devices in a three-phase inverter. However, in the attached image the input 'g' is connected to a Pulse Generator that outputs only a pulse. Probably it is better to use a PWM Generator that would output 6 pulses.
Categories
Find more on Electrical Block Libraries in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!