Why cant I predict kstep ahead when adding System Identification models?
Show older comments
Hello, how are you doing?
I have the following question about System Identification: if I add multiple system identification models, such as ARX models, I obtain as a result a State-space model that ignore the kstep parameter in the prediction.
For example:
load iddata1 z1;
sys = ssest(z1,3);
If i do:
compare(z1,sys,1)
OR
compare(z1,sys,inf)
the results are completely different, as expected!
However, if I have the combination of two models,
sys2 = sys + sys;
when i use compare(z1,sys,inf) or compare(z1,sys,1), the results are the same! It just ignore the kstep parameter!
Can anyone explaine me what is going on? How can I add two systems and still make a 1 step ahead prediction?
PS: sys2 = sys + sys is equivalente to parallel(sys,sys).
Thanks a lot!
Accepted Answer
More Answers (1)
Paresh yeole
on 1 Jun 2020
0 votes
Check this link.
It says :
'compare ignores kstep when sys is an iddata object, an FRD model, or a dynamic system with no noise component. compare also ignores kstep when using frequency response validation data. '
1 Comment
Giulio Cesare Mastrocinque Santo
on 1 Jun 2020
Categories
Find more on Compare Output with Measured Data in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!