Simulation Data Inspector from Test Manager?

1 view (last 30 days)
Matteo Manzini
Matteo Manzini on 30 Jun 2020
Answered: Aman Vyas on 31 Jul 2020
Hello,
I created a test harness for a subsystem and I'm using the Test Manager. I logged the signal I'm interested in but I can't see anything in the Simulation Data Inspector.
Any suggestion?
Thanks!!!

Answers (1)

Aman Vyas
Aman Vyas on 31 Jul 2020
Hi,
Based on your description, I think you created a test harness for a subsystem in your design model, and setup Simulation option 'SIL' for Simulink test using Test Manager.
In test harness, SIL mode is not supported. The reason is that we can create a SIL harness for a subsystem in the design model. During creating the test harness for a subsystem, you can specify the verification mode as "SIL" to create a SIL harness. Then you can use normal simulation mode to simulate the test harness.
Please see the following web page for the detailed explanation about creating a SIL harness for a subsystem. https://www.mathworks.com/help/sltest/ug/silpil-verification-for-a-subsystem.html .
From bulletin 8 and 9, those are the steps to create a SIL harness.
Hope it helps !