my new if statements are not working and do not change my k value
3 views (last 30 days)
Show older comments
I am trying to develop a new P&O algorithm. where I compare 2 points before and after my current power value. in my old code, I was just comparing 2 points (the actual power value and the previous one)and my code was working perfectly fine but when I tried to change the code to compare 2 points after and 2 points before the actual power value, it does not work for some reason.
my old code flow chart 

and here is my old code which is working perfectly.
function k_values=P_and_O(sc,Vi,k)
I_prev=Newton_pv(Vi(sc-1)); % The input current value in the previous cycle
I_actual=Newton_pv(Vi(sc)); % The input current value in the current cycle
P_prev=Vi(sc-1)*I_prev; % To calculate the power value for the previous cycle
P_actual=Vi(sc)*I_actual; % to calculate the power value for the current cycle
delta_V=Vi(sc)-Vi(sc-1); % to calculate the difference between current voltage value and the previous one.
delta_P=P_actual-P_prev; % to calculate the difference between current power value and the previous one.
% if statment used to ecide whether to increase or decrease duty ratio(k) value
% depending on voltage and Power difference values.
if delta_P>0.001
if delta_V>0
k=k-0.0001;
else
k=k+0.0001;
end
elseif delta_P<(-0.001)
if delta_V>0
k=k+0.0001;
else
k=k-0.0001;
end
end
k_values=k; % used to store new k in the output
end
my new code which is not working
% function for Perturb and Observe MPPT algorithm
% function for Perturb and Observe MPPT algorithm
function k_values=P_and_O_NEW(sc,Vi,k)
I_actual=Newton_pv(Vi(sc)); % The input current value in the current cycle
I_prev_1=Newton_pv(Vi(sc-1));
I_prev_2=Newton_pv(Vi(sc-2)); % The input current value in the previous cycle
P_actual=Vi(sc)*I_actual; % to calculate the power value for the current cycle
P_prev_1=Vi(sc-1)*I_prev_1;
P_prev_2=Vi(sc-2)*I_prev_2; % To calculate the power value for the previous cycle
%I_next_1=Newton_pv(Vi(z+1));
%I_next_2=Newton_pv(Vi(z+2));
%P_next_1=Vi(z+1)*I_next_1;
%P_next_2=Vi(z+2)*I_next_2;
if sc <= length(Vi) - 2
I_next_1=Newton_pv(Vi(sc+1));
I_next_2=Newton_pv(Vi(sc+2));
P_next_1=Vi(sc+1)*I_next_1;
P_next_2=Vi(sc+2)*I_next_2;
delta_V= Vi(sc+1)- Vi(sc) ;
delta_V1= Vi(sc+2)-Vi(sc);
delta_P= P_next_1 - P_actual;
delta_P1= P_next_2 - P_actual;
if delta_P>0.001
if delta_V>0
k=k-0.0001;
else
k=k+0.0001;
if delta_P1 >0.001
if delta_V1>0
k=k-0.0001;
else
k=k+0.0001;
end
end
end
else
delta_V_1= Vi(sc)-Vi(sc-4 );
delta_V_2= Vi(sc)-Vi(sc-1);
delta_P_1= P_actual-P_prev_2;
delta_P_2= P_actual-P_prev_1;
% delta_P1= [P_actual-P_prev_2,P_actual-P_prev_1]
%delta_V1=[Vi(z)-Vi(z-2) , Vi(z)-Vi(z-1)]
%delta_V=Vi(z)-Vi(z-1); % to calculate the difference between current voltage value and the previous one.
%delta_P=P_actual-P_prev; % to calculate the difference between current power value and the previous one.
%delta_V=[Vi(z)-Vi(z-2), Vi(z)-Vi(z-1), Vi(z)-Vi(z+1),Vi(z)-Vi(z+2)]
%delta_P=[P_actual-P_prev_2,P_actual-P_prev_1,P_actual-P_next_1,P_actual-P_next_2]
% if statment used to ecide whether to increase or decrease duty ratio(k) value
% depending on voltage and Power difference values.
if delta_P_1<(-0.001)
if delta_V_1>0
k=k+0.0001;
else
k=k-0.0001;
if delta_P_2 <(-0.001)
if delta_V_2>0
k=k+0.0001;
else
k=k-0.0001;
end
end
end
end
end
end
k_values=k; % used to store new k in the output
end