Fourier Analysis of a sound wave.

16 views (last 30 days)
Niall Campbell
Niall Campbell on 20 Oct 2020
Answered: Ayush Bansal on 27 Oct 2020
I have micriphone data which i want to analyse.
The data is in Volts and the microphone sensitivity is 49.5 mV/Pa.
I want to convert the microphone signal into pressure in Pascals, Pa.
The next step is to find the max sound pressure level (SPL) magnitude and the root mean square, RMS, of the signal.
I then want to convert these into sound pressure level in dB.

Answers (1)

Ayush Bansal
Ayush Bansal on 27 Oct 2020
Use Pressure (Pa)=Volts(mv)/sensitivity(mV/Pa) to calculate pressure from voltage.
Use max(A) which returns the maximum element of an array, given A is vector, to find max sound pressure level.
Use rms(x) to find rms of input x.
Use 20log(P/Po), where Po is reference sound pressure 0.000002Pa and P is the pressure, to get values in dB.

Categories

Find more on Audio I/O and Waveform Generation in Help Center and File Exchange

Tags

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!