How can I use a continuous integrator in atomic subsystem?
8 views (last 30 days)
Show older comments
Hello people! In my simulation I must use a fixed step size (0.001 s) with the solver ode3 (Runge-Kutta). There is an atomic subsystem with sample time of 1s in my model,and the atomic subsystem have a continuous integrator in it .
So,when I start the simulation ,I got an error :'... \integrator' has an invalid sample time of [0, 0]. Periodic atomic subsystem 'untitled/Subsystem' may contain only blocks that have constant (inf), inherited (-1), or periodic (1) sample times.
how can I fix it ?thank you very much.
0 Comments
Answers (1)
Ryan G
on 10 Jul 2013
The error you are seeing is effectively saying you cannot have continuous blocks if you define a discrete sample time on the atomic subsystem. You can use a discrete integrator to resolve this. Since you are taking such large steps I would imagine that the results would be comparable.
0 Comments
See Also
Categories
Find more on General Applications in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!