Clear Filters
Clear Filters

How can I simulate no-load saturation of a synchronous machine?

1 view (last 30 days)
I built a minimum example:
1) one synchronous machine pu standard
- Parameters set to an arbitrary preset model
- Saturation on
- Load Flow set to PQ, both set to zero
2) one three phase source
3) one load flow bus
- Voltage set to 1.1 pu
.
I use Powergui Load Flow to calculate the initial state.
Result of Calculation:
- Constant at power-input of machine is zero. That´s OK.
- Constant at exciter input of machine is 1.1. That´s not OK. Due to activated saturation I expect another value. It should be possible to point-wise calculate the no-load saturation curve (which is the input parameter of the saturation of machine) of the machine by adjusting the voltage setpoint of the load flow bus and keeping P=Q=0.
What is my mistake?
Thanks!

Answers (1)

Juan Sagarduy
Juan Sagarduy on 26 Oct 2020
Hi Matthias
I would give this a go with a recent release of Simscape Electrical where we have added load flow analysis and synchronous machines simulate well with open windings.
I am under the impression that your system is over-constrained.
Br Juan

Categories

Find more on Electrical Sensors in Help Center and File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!